Title: Loudspeaker impedance – Audio Lab
---

# Loudspeaker impedance (Impedance)

The electrical impedance of a bare driver or a loaded cabinet over frequency, from a small external
current-sense jig through the headphone/monitor output. For a driver measured free in the air: Fs, Re, Zmax,
Zmin and the Thiele-Small Qms/Qes/Qts. For a vented box or one with a passive radiator (two resonance peaks):
Fb, the tuning frequency, instead.

## At a glance

| Task | What it tells you | Wiring | Level | A good result |
| --- | --- | --- | --- | --- |
| **Impedance** | Z(f) magnitude and phase; Fs, Re, Zmax, Zmin, nominal Z, Qms/Qes/Qts (one peak) or Fb (two peaks) | Mono, reference before R1 (IN 3), device output at the DUT (IN 4) | moderate – see *Level and safety* below | close to the datasheet, or self-consistent before/after a change |

The maths behind this: [Methods → Loudspeaker impedance](methods.html#14-loudspeaker-impedance).

## How it works

The jig puts a small sense resistor **R1** in series with the driver and a selector switch **SW2** that
either connects the driver (**SPEAKER**) or a reference resistor **R2** (**CAL**, for the jig's own
self-calibration – see below). A second switch, **SW1**, picks what IN 4 itself reads – the node after R1
(**MEASURE**, the normal position) or the same node IN 3 already reads (**CHANNEL CAL**) – see *Calibration*
below.

![The actual build: the interface output (Motu phone output) feeds R1 in series with the driver; Motu IN 3 reads the node before R1; SW1 (MEASURE – CHANNEL CAL) picks what Motu IN 4 reads, the node after R1 or the same node IN 3 reads; SW2 (SPEAKER – CAL) picks the driver or the reference resistor R2, in series to ground](figures/speaker_impedance.png)

IN 3 and IN 4 are exactly the reference and output Audio Lab already reads for Gain & phase, so the task reuses
the same chirp and the same H1 transfer function – nothing new on that side. Writing the DUT current as
**I = (IN 3 − IN 4) / R1** and H = IN 4 / IN 3 (the usual transfer function):

**Z = IN 4 / I = R1 · H / (1 − H)**

The chart plots **|Z|** on a log axis against frequency, with phase on a second axis.

## Calibration

Two one-time steps, both from Task info (ⓘ) → the checklist there shows which are done:

1. **Channel loop** (SW1 → CHANNEL CAL): a short sweep with IN 3 and IN 4 on the same node, so the two inputs'
   own small gain/phase difference is measured and taken out – the same loop-correction mechanism as
   Frequency response.
2. **Reference-resistor self-calibration** (SW2 → CAL): a short sweep against R2 finds the jig's *effective*
   R1 (a real resistor is rarely exactly 47 Ω), without needing to desolder or measure it directly. A reading
   far from the expected reference value is flagged – check SW1/SW2 and the wiring first.

Both are saved and reused across sessions; recalibrate only if the jig itself changes.

## Steps

1. Task info (ⓘ) → **Set connections**: Mono wiring, reference In 3, device output In 4, generator outputs
   1–2 – nothing to pick wrong by hand.
2. Calibrate the jig once (above), if the checklist says it is not done yet.
3. Enter **Re**, the DUT's DC voice-coil resistance from a multimeter across its own terminals – needed for
   Qms/Qes/Qts; without it the task still reports Fs, Zmax and Zmin.
4. SW2 → **SPEAKER**, connect the driver or cabinet, **RUN**.
5. Read the chart and the bar: one peak gives Fs/Zmax/Qms/Qes/Qts, two peaks (a vented box or one with a
   passive radiator) give Fb instead – the formula for Q assumes a single resonance and would be meaningless
   applied to a box tuning.

### Level and safety

Start low (around −20 dBFS) and raise it only as far as needed for a clean reading – the jig drives the DUT
directly from the output, so an unexpectedly loud level is a real signal into the driver, not just a reading
on a meter.

## Mounting matters more than the jig

A driver's free-air Fs and Qms describe its suspension alone – they are only valid when nothing else touches
or loads the moving system. Resting a bare driver on a surface, even gently on its magnet, lightly damps and
loads it: Fs reads low, the peak is flattened, and Qms in particular is suppressed, since it responds directly
to extra mechanical friction. Suspend it – a string, a stand, or holding it clear of everything – before
reading Thiele-Small figures. A worked example with the same driver measured both ways:
[Pioneer TS-H1303, measured](measured-pioneer-ts-h1303.html).