# Measured devices

Devices measured with AudioLab, each with its full protocol: how it was wired, every setting, every reading with its chart and CSV, and what the setup itself limits. The protocols name the maker and model; each describes one unit.

All of them were measured with the same interface, a MOTU M4 at 48 kHz, and are read against its own floor, measured first in a loop. How to do the same with your own devices: the step-by-step guides under *Devices* – [your interface first](step-interface.html), [a headphone amplifier](step-headphone-amp.html), [a USB audio card](step-usb-card.html).

| Device | Kind | Measured | In short | Protocol |
| --- | --- | --- | --- | --- |
| **MOTU M4** | audio interface, the measuring one | November 2026 | input noise 14.4 µV (10.8 µV A); THD −105 to −111 dB; IMD SMPTE 0.0011–0.0016 %; response with loop correction ±0.1 dB | [protocol](measured-motu-m4.html) |
| **Behringer UFO202** | USB audio card: phono/line input, line and headphone output | November 2026 | line input 0.0016 % THD, 90.5 dB(A); output 0.0074 % THD+N, 95 dB(A); phono −6.3 dB at 20 Hz against RIAA; headphone output 50 Ω | [protocol](measured-behringer-ufo202.html) |
| **Aune T1** | headphone amplifier, line input to headphone output | November 2026 | output impedance 15 Ω; about 640 mW into 32 Ω at 1 %; response within 0.01 dB; noise 12 µV (6 µV A); crosstalk −28 dB into 32 Ω | [protocol](measured-aune-t1.html) |

## How the protocols are built

- **Summary** first: the main figures, each with the section it comes from.
- **How it was measured:** the wiring with a drawing, the interface, cables, attenuators and load boxes, and the settings common to all readings.
- **Measurements**, numbered: why each reading is taken, the exact settings, the chart, a table of the figures, what they mean – and the CSV export to check them.
- **Limits:** what the setup cannot tell apart from the device, and what was not measured.

A figure within a few dB of the interface's floor is marked as such: there the reading shows the setup as much as the device.