Fourteen definitions ship with the program: ten verified, four draft.
The list is short on purpose. Adding a name to a menu is easy; being able to say why a reading is right is not. Every definition here either has a recording behind it or is marked as not having one.
The protocol definitions repository on GitHub contains the JSON files, their schema and contribution guidelines.
| verified | A real recording has been decoded with it and the result checked – ideally against an independent reading of the same signal, such as a Flipper's own decode of the same button press, or rtl_433's output for the same sensor. The definition carries that recording as a test, so a later change that breaks it fails the build. |
|---|---|
| draft | Written from a datasheet, from somebody else's firmware, or from a recording that was not conclusive. It is ranked lower, because a definition that has never met a signal will cheerfully match ones it has nothing to do with – especially a short frame with no checksum, which cannot be told from noise on its own. |
This distinction is not bureaucracy. One of the definitions below decoded its test recording perfectly — and backwards. Only a second, independent reading of the same button press showed it, and the bit order was inverted as a result.
| Protocol | Status | Frame | Notes |
|---|---|---|---|
EV1527ev1527 |
verified | 24 bit, PWM | The most common cheap 433 MHz remote and PIR encoder: 20 bits of identifier, 4 of button. |
PT2262pt2262 |
verified | 12 tri-state, PWM | Older encoder whose address and data lines carry three states, not two. Read as tri-state rather than forced into binary. |
CAME 18-bitcame-18 |
verified | 18 bit, PWM | Used by appliance remotes as well as gates. Verified against a Flipper RAW and Key pair, which is what revealed the inverted bit order. |
GateTXgate-tx |
verified | 24 bit, PWM | Verified against a paired RAW and Key capture from a TX028C-S ceiling-fan remote. |
Somfy RTSsomfy-rts |
verified | 56 bit, Manchester | Blind and awning remote on the unusual 433.42 MHz. Identification only – it is a rolling code, and the payload is obfuscated. |
KeeLoqkeeloq |
draft | 66 bit, PWM | Gate, garage and alarm remotes with a Microchip HCS encoder. Identification only – the frame is split into its encrypted part, serial number and buttons, and nothing is decrypted. Draft because a rolling-code recording cannot be published as its evidence. |
CAME 12-bitcame |
draft | 12 bit, PWM | Gate and garage remotes in their twelve-bit form, and the many clones of it. |
Nice FLOnice-flo |
draft | 12 bit, PWM | Fixed code, frames separated by a gap alone and no checksum – which is precisely why it stays a draft: there is nothing in the frame to tell it apart from noise. |
Holtek HT12Xholtek-ht12x |
draft | 12 bit, PWM | From the datasheet and a 315 MHz sweep recording. The framing is consistent at a measured 430 µs element, but the frame is ambiguous with CAME and no paired decoded key has confirmed it. |
| Protocol | Status | Frame | Notes |
|---|---|---|---|
Nexus-THnexus-th |
verified | 36 bit, PPM | A very common cheap outdoor temperature and humidity sensor, sold under many names. |
Fine Offset WH2fineoffset-wh2 |
verified | 48 bit, PWM | Also sold as Agimex Rosenborg 66796 and various Clime models. |
Acurite 609TXCacurite-609txc |
verified | 40 bit, PPM | Outdoor sensor for the 00609 and similar displays. |
LaCrosse TX141TH-Bv2lacrosse-tx141thb2 |
verified | 40 bit, PWM | Verified against a Flipper RAW and decoded Key pair: the identifier, temperature and humidity all agree, and the digest checks out. |
Bresser 6-in-1bresser-6in1 |
verified | 144 bit, FSK, PCM | The first FSK definition: framed on the sync word 0x2dd4 and protected by a
16-bit LFSR digest. Only the identifier, sensor type and channel are declared; temperature,
humidity, wind and rain are packed in a way the schema cannot describe yet. |
A definition is a small JSON file against a
schema published in the definitions repository
– radio parameters, timing,
coding, frame layout, fields and a check – not code. Put yours in your own folder
(Settings → Protocol definitions) and it is loaded after the built-in ones, so
a definition with the same id replaces one that ships with the program. That is how you
fix a shipped definition without waiting for a release.
Supported today:
| Modulation | OOK/ASK end to end, and 2-FSK through the PCM coding, which
frames the demodulated bit stream on a sync word. 4-FSK and PSK are demodulated and give bits,
but a definition cannot be driven from them yet, so that work continues in
Bits. |
|---|---|
| Coding | PWM, PPM, Manchester (both conventions), NRZ, differential Manchester, PCM |
| Checks | Parameterised CRC-8 and CRC-16, byte sum, XOR, LFSR digest |
| Fields | Unsigned, signed, BCD, with scale and offset – so a sensor reads in °C and per cent, not in hex |
The shipped definitions are released under CC0 1.0: use them anywhere, including in rtl_433, ESPHome or Flipper firmware, without asking and without credit.